Abstract
In the current context of COVID-19 pandemic, a rapid and accessible screening tool based on image processing of chest X-rays (CXRs) using machine learning (ML) approaches would be much needed. Initially, we intended to create and validate an ML software solution able to discriminate on the basis of the CXR between SARS-CoV-2-induced bronchopneumonia and other bronchopneumonia etiologies.
A systematic search of PubMed, Scopus and arXiv databases using the following search terms [“artificial intelligence” OR “deep learning” OR “neural networks”], AND [“COVID-19” OR “SARS-CoV-2”] AND [“chest X-ray” OR “CXR” OR “X-ray”] found 14 recent studies. Most of them declared to be able to confidently identify COVID-19 based on CXRs using deep neural networks. Firstly, weaknesses of artificial intelligence (AI) solutions were analyzed, tackling the issues with datasets (from both medical and technical points of view) and the vulnerability of used algorithms. Then, arguments were provided for why our study design is stronger and more realistic than the previously quoted papers, balancing the possible false expectations with facts.
The authors consider that the potential of AI use in COVID-19 diagnosis on CXR is real. However, scientific community should be careful in interpreting statements, results and conclusions regarding AI use in imaging. It is therefore necessary to adopt standards for research and publication of data, because it seems that in the recent months scientific reality suffered manipulations and distortions. Also, a call for responsible approaches to the imaging methods in COVID-19 is raised. It seems mandatory to follow some rigorous approaches in order to provide with adequate results in daily routine. In addition, the authors intended to raise public awareness about the quality of AI protocols and algorithms and to encourage public sharing of as many CXR images with common quality standards.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
NCT04313946
Funding Statement
This study was funded by the Romanian Academy of Medical Sciences and European Regional Development Fund, MySMIS 107124: Funding Contract 2/Axa 1/31.07.2017/ 107124 SMIS
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data used to support the findings of this study are available from the corresponding author upon request.