Abstract
By the third week of June 2020, more than 8,500,000 positive cases of COVID-19 and more than 450,000 deaths had been officially reported worldwide. The COVID-19 pandemic arrived in Latin America, India, and Africa—territories in which the mounted infrastructure for diagnosis is greatly underdeveloped. Here, we demonstrate the combined use of a three-dimensional (3D)-printed incubation chamber for commercial Eppendorf PCR tubes, and a colorimetric embodiment of a loop-mediated isothermal amplification (LAMP) reaction scheme for the detection of SARS-CoV-2 nucleic acids. We used this strategy to detect and amplify SARS-CoV-2 genetic sequences using a set of in-house designed initiators that target regions encoding the N protein. We were able to detect and amplify SARS-CoV-2 nucleic acids in the range of 62 to 2 × 105 DNA copies by this straightforward method. Using synthetic SARS-CoV-2 samples and a limited number of RNA extracts from patients, we also demonstrate that colorimetric LAMP is a quantitative method comparable in diagnostic performance to RT-qPCR. We envision that LAMP may greatly enhance the capabilities for COVID-19 testing in situations where RT-qPCR is not feasible or is unavailable. Moreover, the portability, ease of use, and reproducibility of this strategy make it a reliable alternative for deployment of point-of-care SARS-CoV-2 detection efforts during the pandemics.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The authors acknowledge funding provided by Consejo Nacional de Tecnologia y Ciencias (CONACyT), Mexico. The authors acknowledge funding provided by Catedra Baur.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data related to the research described in this manuscript has been made available within the text and figures within the manuscript or as supplemental material.