Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety

View ORCID ProfileAurora Baluja, View ORCID ProfileJusto Arines, Ramon Vilanova, Julio Cortiñas, View ORCID ProfileCarmen Bao-Varela, View ORCID ProfileMaria Teresa Flores-Arias
doi: https://doi.org/10.1101/2020.04.07.20057224
Aurora Baluja
1 Department of Anesthesiology and Critical Care. FIDIS Health Research Institute. Hospital Clinico Universitario de Santiago de Compostela;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Aurora Baluja
  • For correspondence: mariauror@gmail.com
Justo Arines
2 Photonics4Life research group, Optics Area, Department of Applied Physics, Universidade de Santiago de Compostela;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Justo Arines
  • For correspondence: justo.arines@usc.es
Ramon Vilanova
3 Iberman Group. University Hospital. Santiago de Compostela. Spain;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: rvilanova@ibermansa.com
Julio Cortiñas
4 Department of Anaesthesiology and Critical Care. Hospital Clinico Universitario. FIDIS Health Research Institute. Santiago de Compostela, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: jacd.tilo@gmail.com
Carmen Bao-Varela
2 Photonics4Life research group, Optics Area, Department of Applied Physics, Universidade de Santiago de Compostela;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Carmen Bao-Varela
  • For correspondence: carmen.bao@usc.es
Maria Teresa Flores-Arias
2 Photonics4Life research group, Optics Area, Department of Applied Physics, Universidade de Santiago de Compostela;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Maria Teresa Flores-Arias
  • For correspondence: maite.flores@usc.es
  • Abstract
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Background and Objectives: The SARS-CoV-2 pandemic has led to a global decrease in personal protective equipment (PPE), especially filtering facepiece respirators (FFRs). Ultraviolet-C wavelength is a promising way of decontamination, however adequate dosimetry is needed to ensure balance between over and underexposed areas and provide reliable results. Our study demonstrates that UVGI light irradiance varies significantly on different respirator angles and propose a method to decontaminate several masks at once ensuring appropriate dosage in shaded zones. Methods: An UVGI irradiator was built with internal dimensions of 69.5 x55 x 33 cm with three 15W UV lamps. Inside, a grating of 58 x 41 x 15 cm was placed to hold the masks. Two different flat fold respirator models were used to assess irradiance, four of model Aura 9322 3M of dimensions 17 x 9 x 4cm (tri-fold), and two of model SAFE 231FFP3NR (bi-fold) with dimensions 17 x 6 x 5 cm. A spectrometer STN-SilverNova was employed to verify wavelength spectrum and surface irradiance. A simulation was performed to find the irradiance pattern inside the box and the six masks placed inside. These simulations were carried out using the software DIALUX EVO 8.2. Results: The data obtained reveal that the irradiance received inside the manufactured UVGI-irradiator depends not only on the distance between the lamps plane and the base of the respirators but also on the orientation and shape of the masks. This point becomes relevant in order to assure that all the respirators inside the chamber receive the correct dosage. Conclusion: Irradiance over FFR surfaces depend on several factors such as distance and angle of incidence of the light source. Careful irradiance measurement and simulation can ensure reliable dosage in the whole mask surface, balancing overexposure. Closed box systems might provide a more reliable, reproducible UVGI dosage than open settings.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This work was partially supported by the Conselleria de Educacion Program for Development of a Strategic Grouping in Materials - AeMAT Grant No. ED431E2018/08 and Xunta de Galicia ref. ED431B2017/64.

Author Declarations

All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.

Yes

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Updated preprint structure to improve legibility

Data Availability

Available data are included in the manuscript

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted August 07, 2020.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety
Aurora Baluja, Justo Arines, Ramon Vilanova, Julio Cortiñas, Carmen Bao-Varela, Maria Teresa Flores-Arias
medRxiv 2020.04.07.20057224; doi: https://doi.org/10.1101/2020.04.07.20057224
Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
Citation Tools
UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety
Aurora Baluja, Justo Arines, Ramon Vilanova, Julio Cortiñas, Carmen Bao-Varela, Maria Teresa Flores-Arias
medRxiv 2020.04.07.20057224; doi: https://doi.org/10.1101/2020.04.07.20057224

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Health Policy
Subject Areas
All Articles
  • Addiction Medicine (62)
  • Allergy and Immunology (141)
  • Anesthesia (44)
  • Cardiovascular Medicine (408)
  • Dentistry and Oral Medicine (67)
  • Dermatology (47)
  • Emergency Medicine (141)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (171)
  • Epidemiology (4805)
  • Forensic Medicine (3)
  • Gastroenterology (177)
  • Genetic and Genomic Medicine (670)
  • Geriatric Medicine (70)
  • Health Economics (187)
  • Health Informatics (621)
  • Health Policy (314)
  • Health Systems and Quality Improvement (200)
  • Hematology (84)
  • HIV/AIDS (155)
  • Infectious Diseases (except HIV/AIDS) (5278)
  • Intensive Care and Critical Care Medicine (323)
  • Medical Education (91)
  • Medical Ethics (24)
  • Nephrology (73)
  • Neurology (677)
  • Nursing (41)
  • Nutrition (110)
  • Obstetrics and Gynecology (124)
  • Occupational and Environmental Health (203)
  • Oncology (437)
  • Ophthalmology (138)
  • Orthopedics (36)
  • Otolaryngology (88)
  • Pain Medicine (35)
  • Palliative Medicine (15)
  • Pathology (127)
  • Pediatrics (193)
  • Pharmacology and Therapeutics (129)
  • Primary Care Research (84)
  • Psychiatry and Clinical Psychology (765)
  • Public and Global Health (1796)
  • Radiology and Imaging (321)
  • Rehabilitation Medicine and Physical Therapy (138)
  • Respiratory Medicine (255)
  • Rheumatology (86)
  • Sexual and Reproductive Health (68)
  • Sports Medicine (61)
  • Surgery (100)
  • Toxicology (23)
  • Transplantation (28)
  • Urology (37)