Abstract
Objectives Consumer-based accelerometers (activity trackers) are increasingly used in research. The aim of this study was to test the validity of the Polar Vantage watch and Oura ring activity trackers for measuring physical activity (PA), total energy expenditure (EE), resting heart rate (RHR), and sleep duration, when worn by adults in free-living.
Design, setting, and participants Twenty-one participants wore four activity trackers; Polar, Oura, ActiGraph, and Actiheart, and completed a sleep diary for up to seven days. We assessed criterion validity of Polar and Oura when measuring PA, TEE, RHR (Oura), and sleep duration. We analysed repeated measures correlation, Bland-Altman plots, and mean absolute percentage error (MAPE).
Results Polar and Oura were both strongly correlated (p<0.001) with ActiGraph for steps (Polar r 0.75, 95% CI 0.54-0.92. Oura r 0.77, 95% CI 0.62-0.87), moderate-to-vigorous PA (MVPA) (Polar r 0.76, 95% CI 0.62-0.88. Oura r 0.70, 95% CI 0.49-0.82), and TEE (Polar r 0.69, 95% CI 0.48-0.88. Oura r 0.70, 95% CI 0.51-0.83) and strongly or very strongly correlated (p<0.001) with the sleep diary for sleep duration (Polar r 0.74, 95% CI 0.56-0.88. Oura r 0.82, 95% CI 0.68-0.91). Oura was very strongly correlated (p<0.001) with Actiheart for RHR (r 0.9, 95% CI 0.85-0.96). MAPE was high for all variables except Oura sleep duration (10%), and RHR (3%) where Oura under-reported on average one beat per minute.
Conclusions Oura can potentially be used as an alternative to Actiheart to measure RHR. For sleep duration, Polar and Oura can potentially be used as a replacement for a manual sleep diary. Neither Polar nor Oura can replace ActiGraph for measuring steps, MVPA, and TEE, but may be used as an additional source of PA in some settings.
Strengths and limitations of this study
Major strength is the analysis of multiple days of recordings instead of one mean measure per participant
Wide ranges of participant age, height, weight, body mass index, and gender balance
Main limitation is the use of criteria validated using gold standards, but are not themselves considered gold standard in all settings
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by UiT The Arctic University of Norway’s thematic priority grant “Personalized medicine for public health”. The publication charges for this study were granted from the publication fund at UiT The Arctic University of Norway.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data is available from the first author upon reasonable request
Abbreviations
- AEE
- Activity energy expenditure
- EE
- Energy expenditure
- HR
- Heart rate
- RHR
- Resting heart rate
- MAPE
- Mean absolute percentage error
- MVPA
- Moderate-to-vigorous physical activity
- PA
- Physical activity
- PSG
- Polysomnography
- TEE
- Total energy expenditure
- RMC
- Repeated measures correlation