Abstract
Background parenchymal enhancement (BPE) on multi-parametric breast magnetic resonance imaging (mpMRI) reflects the volume and intensity of gadolinium uptake. We developed a semi-automated segmentation algorithm to extract and quantify measures of BPE and investigated the agreement of computed measures of BPE with radiologist-assigned categories. We retrospectively identified 123 high risk patients with breast mpMRI performed for screening indications. Pre- and post-gadolinium T1-weighted series with and without fat suppression were co-registered. Using Otsu’s method and an active contours method, the breast tissue was segmented from the chest wall and non-fat voxels were clustered to identify the amount of fibroglandular tissue. Median and inter-quartile ranges for the absolute volume of BPE (BPE cm3) and the percentage of BPE (BPE%) using a threshold PE of 30% were computed within the segmented FGT on the first post-contrast phase. Student’s t-test was used to evaluate BPE volume and BPE% by radiologist-assigned categories. Both BPE volume and BPE% differed significantly between minimal/mild and moderate/marked radiologist assigned categories (p=0.030 and 0.004, respectively). Using our newly developed semi-automated segmentation pipeline, we quantified fibroglandular tissue and BPE. The overlapping ranges of quantitative BPE corresponding to the radiologist-assigned BPE categories showcases the inter-reader variability with visual estimation of BPE.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external funding was provided for this project.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data would be available upon request following publication.