ABSTRACT
Background It is imperative that non-compliance to statins be identified and addressed to optimize the clinical benefit of statins. Patient self-reporting methods are convenient to apply in clinical practice but need to be validated.
Objective We studied the concordance of a patient self-report method, MMAS (Morisky eight item medication adherence scale) with pill count method in measuring adherence to statins and their correlation with extended lipid profile parameters and serum HMGCoA-R (hydroxymethylglutaryl coenzyme A reductase) enzyme levels.
Methods MMAS and pill count method were used to measure the adherence to statins in patients on statins for any duration. Patients were subjected to estimation of extended lipid profile and serum HMGCoA-R levels at the end of 3 months follow-up.
Results Out of a total of 200 patients included in the study, 117 patients had low adherence (score less than 6 on MMAS) whereas 65 and 18 patients had medium (score 6 to less than 8) and high adherence (score of 8) respectively. Majority of patients who had low adherence to statins by MMAS were nonadherent by pill count method yielding concordance of 96.5%. Medium or high adherence to statins by MMAS method had concordance of 89.1% with pill count method. The levels of total cholesterol, low density lipoprotein-cholesterol, apolipoprotein B and HMGCoA-R were significantly negatively correlated with compliance measured by pill count and MMAS with similar correlation coefficients. HMGCoA-R levels demonstrated a plateau phenomenon with levels being 9-10 ng/ml when compliance to statin therapy was greater than 60% by pill count and greater than 6 on Morisky scale.
Conclusion In conclusion, MMAS and pill count methods showed concordance in measuring adherence to statins. These methods need to be explored further for their interchangeability as surrogates for biomarker levels.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
None
Author Declarations
All relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
Any clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.
Not Applicable
I have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.
Not Applicable
Footnotes
Conflicts of interest: none Relationship with industry: none Authors’ Contributions
Abhinav Grover- Hypothesis generation, protocol writing, estimation of various parameters, data analysis, manuscript writing
Mansi Oberoi – Data analysis, manuscript writing
Madhur Yadav-Screening of the patients
Lalit Kumar Gupta- Data handling, critical evaluation of manuscript
Harmeet Singh Rehan-Hypothesis generation, manuscript writing
Data Availability
NA